C
Commercialpedia Indian Railways commercial circulars and policies

Standardization of amenities for Freight terminals (Goods Shed) for facilitating night loading/unloading

No. 2004/Elect(G)/109/1/Pt.01 · 2008-06-12
Historical — likely supersededCircularfreight
Historical — likely superseded. This circular predates 2020 and has probably been replaced. Treat it as a record of what the rule was, not what it is. The official Railway Board PDF always prevails over anything shown here.

No official Railway Board PDF has been traced for this entry yet. The text below was read from the document held in the library.

Circular numberNo. 2004/Elect(G)/109/1/Pt.01
Date2008-06-12
TypeCommercial Circular
Topicfreight
CurrencyHistorical — likely superseded

Summary

Standardization of amenities for Freight terminals (Goods Shed) for facilitating night loading/unloading for opening of new goods shed and improving amenities in old goods shed so that

Text of the circular

GOVERNMENT OF INDIA
MINISTRY OF RAILWAYS
(RAILWAY BOARD)

No. 2004/Elect(G)/109/1/Pt.01 Dated 12.06.2008

General Managers
All Indian Railway.

Director General, Staff College, Vadodara,
Director General, RDSO, Lucknow

Sub: Standardization of amenities for Freight terminals (Goods Shed) for
facilitating night loading/unloading.

Ref : (i) Item No. 2 of Hon’ble MR’s speech in General Manger’s
Conference held in Board’s Office on 26™ May, 2008
(ii) Boards Letter No. 2007/PL/25/1 dated 5/6/07

Hon’ble MR. during GM Conference held in Board’s Office has emphasized
for opening of new goods shed and improving amenities in old goods shed so that
loading/unloading can be done round the clock.

2.0 As there is no norms specified for standardization of illuminating level in
areas related with goods sheds. Based on BEE Code a policy has been framed to
specify illumination level at various points of goods shed at Annexe-A.

3.0  Fannage for goods yard shed has been recommended as per scale of
provision of fan at waiting room and offices at Railway stations as per Board’s
letter no. 86/Elec/1/138/1 dated 2.12.1988.

4.0 Railway must plan facilities based on above recommendations in all
existing/new goods shed. The feed back in this regard shall be submitted t Va
Office on six monthly basis.

a Jain)
Director Electrical Engg.(PS)
Railway Board.

Copy to:
1. Advisor (L&A), Railway Board,
2. Executive Director(PM), Railway Board.
3. CEEs(All Zonal Railways) for information and necessary action.
4. ED(PS&EMU) RDSO for information and necessary action

-67-

रन

Annexure-A

Scale of. amenities for Goods shee Goods shed (Electrical items)

amenities ior sore

illumination Level for Freight terminals (Goods shed) for facilitating night
loading/unloading

Proposed Suggested Luminaries*

Lux level

As per BEE
Code lux
level

Location

Circulating area —— mast/MH/Tubular/T5*
Loading unloading area
(i)Covered latform+ 30

(ii)Open platform+ 20 i
Merchant room 150 T
Booking office 150 T
* Colour —day light white

Note: Lighting circuit must be provided with programmable timer control

i
|
|

20 Cold water dispensers

1.0  Fannage - One fan of 1500 mm sweep for every 10 square metre in merchant
room and booking office

_ &-

d

जा हा राह) हा गे यार Si Oo) Oy UH