C
Commercialpedia Indian Railways commercial circulars and policies

Promotion to Gr.B posts against 70 Quota-(ASTE) SHIFT - 1

· 2025-05-18
Exam paperticket-checking

No official Railway Board PDF has been traced for this entry yet. The text below was read from the document held in the library.

Date2025-05-18
TypeCommercial Circular
Topicticket-checking

Summary

systems in on-board Kavach include _____________ Automatic signal shall not assume OFF aspect unless the line is clear upto a distance of ______ mtrs beyond the next stop signal in advance if the signal happens to be a

Text of the circular

QUESTION PAPER
Promotion to Gr.B posts against 70% Quota-(ASTE) [SHIFT - 1]
Exam Date : 18/05/2025
Time : 03:00 PM - 05:00 PM
Part A
Question 1
Question Id : 991
RTUs are used in ____________.
आर.टी.यू. का प्रयोग _______ में किया जाता है।
Answer :
Option Id
(A) 
991001
(B) 
991002
(C) 
991003
(D) 
991004
Right Answer :
All the options
सभी विकल्प
Right Option Id : 991004
Question 2
Question Id : 992
Maximum number of dataloggers that the CMU can retrieve data from is _________.
सीएमयू द्वाारा डेटा प्राप्त करने वाले डेटालॉगर्स की अधिकतम संख्या ______ है।
Answer :
Option Id
(A) 
992001
(B) 
992002
(C) 
992003
(D) 
992004
Right Answer :
32
Right Option Id : 992003
Question 3
Question Id : 993
The earth resistance of the earth connected to the EI shall be less than _________.
ईआई से जुड़ेे एर्थ का एर्थ प्रतिरोध ______ कम से कम होगा
Answer :
Option Id
(A) 
993001
(B) 
993002
(C) 
993003
(D) 
993004
Right Answer :
1 ohms
1 ओम
Right Option Id : 993001
Question 4
Question Id : 994
The minimum insulation resistance of a signalling cable shall be _________.
सिगनलिंंग केबल का न्यूनतम इन्सुलेशन प्रतिरोध ______________होगा।
Level crossing gates
लेवल क्रॉसिंंग गेट
IBS
आई बी एस
Auto huts
ऑटो हट्स
All the options
सभी विकल्प
64
30
32
128
1 ohms
1 ओम
10 ohms
10 ओम
0.1 ohm
0.1 ओम
.01 ohm
.01 ओम

Answer :
Option Id
(A) 
994001
(B) 
994002
(C) 
994003
(D) 
994004
Right Answer :
5 mega ohms/km
5 मेगा ओम/किमी
Right Option Id : 994001
Question 5
Question Id : 995
Concrete sleepers that are used in track circuited areas shall have a minimum resistance between insert to insert of_____________.
ट्रैैक सर्किट वाले क्षेत्रों में प्रयोग किए जाने वाले कंक्रीट स्लीीपरों में इन्सर्ट से इन्सर्ट के बीच न्यूनतम प्रतिरोध ______ होना चाहिए।
Answer :
Option Id
(A) 
995001
(B) 
995002
(C) 
995003
(D) 
995004
Right Answer :
500 ohms
500 ओम
Right Option Id : 995002
Question 6
Question Id : 996
Iron screening shall be provided in the event of any metallic part falling within _____ meters of the 25 KV live conductor.
25 केवी लाइव कंडक्टर के _____ मीटर के भीतर किसी भी धातु भाग के आने की स्थिति में आयरन स्क्रीीनिंंग उपलब्ध की जाएगी।
Answer :
Option Id
(A) 
996001
(B) 
996002
(C) 
996003
(D) 
996004
Right Answer :
2 mtrs
2 मीटर
Right Option Id : 996001
Question 7
Question Id : 997
The current rating of a battery charger is 35 amps and the load current at the station is 15 amps, the maximum AH capacity of the battery bank to be used is________.
एक बैटरी चार्जर की करंट रेटिंंग 35 एम्पि
यर है तथा स्टेशन पर लोड करंट 15 एम्पि
यर है, उपयोग की जाने वाली बैटरी बैंक की अधिकतम एएच क्षमता ______ है।
Answer :
Option Id
(A) 
997001
(B) 
997002
(C) 
997003
(D) 
997004
5 mega ohms/km
5 मेगा ओम/किमी
10 mega ohms/km
10 मेगा ओम/किमी
100 mega ohms/km
100 मेगा ओम/किमी
1 mega ohm/km
1 मेगा ओम/किमी
10 mega ohms
10 मेगा ओम
500 ohms
500 ओम
100 ohms
100 ओम
1 mega ohm
1 मेगा ओम
2 mtrs
2 मीटर
4 mtrs
4 मीटर
2.5 mtrs
2.5 मीटर
5 mtrs
5 मीटर
200 AH
200 एएच
120 AH
120 एएच
80 AH
80 एएच
300 AH
300 एएच

Right Answer :
200 AH
200 एएच
Right Option Id : 997001
Question 8
Question Id : 998
The maximum permitted length of direct feed of signals in double line sections shall be ______________.
दोहरी लाइन सेक्शन में सिगनलों के डैरेक्ट फीड की अधिकतम स्वीकृत लंबाई ______ होगी।
Answer :
Option Id
(A) 
998001
(B) 
998002
(C) 
998003
(D) 
998004
Right Answer :
220 mtrs
220 मीटर
Right Option Id : 998002
Question 9
Question Id : 999
The S&T work that shall be completed before issue of certificate for 2.2 KV anti theft charging __________.
2.2 केवी एंटी थेफ्ट चार्जिंग के लिए प्रमाण पत्र जारी करने से पहले पूरा किया जाने वाला एस एंड टी कार्य _____होगा।
Answer :
Option Id
(A) 
999001
(B) 
999002
(C) 
999003
(D) 
999004
Right Answer :
All the options
सभी विकल्प
Right Option Id : 999004
Question 10
Question Id : 1000
The minimum excitation voltage of DC track relays of 125% of pick up voltage shall be under ____ ballast resistance condition with normal working voltage.
125% पिक अप वोल्टेज के डीसी ट्रैैक रिले का न्यूनतम एक्साइटे